EasyManua.ls Logo

Elkay ERPA2-8C*A User Manual

Elkay ERPA2-8C*A
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
97876C (REV. D - 12/04)
ERPA2-8C*A ERPA2-8RAC*A ERPAVR2-8C*A ERPAVR2-8RAC*A LPTEA8C*A LPTEA8RAC*A
Installation/Care/Use Manual
SwirlFlo
®
Refrigerated Fountains with FLEXI-GUARD
®
To assure you install this model easily and correctly, PLEASE READ
THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLA-
TION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After
installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
FIG. 2
FIG. 1
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-
TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
IMPORTANT! INSTALLER PLEASE NOTE.
Installer
NOTE: WATER FLOW
DIRECTION
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
NOTE: WHEN INSTALLING
REPLACEMENT BUBBLER
AND PEDESTAL, TIGHTEN
NUT (ITEM 5 OR 33) ONLY
TO HOLD PARTS SNUG
IN POSITION. DO NOT
OVER TIGHTEN.
FIG. 3
2
3
4
5
1
36
35
SEE FIG. 4 OR 5
37, 39, 41
38, 40, 41
42
SEE FIG. 11
44
44
FIG. 4
45
46
BASIN
47
48
ERPA2-8RAC, LPTEA8RAC
FIG. 5
51
49
33
ERPA2-8C, LPTEA8C
Question and Answer IconNeed help?

Do you have a question about the Elkay ERPA2-8C*A and is the answer not in the manual?

Elkay ERPA2-8C*A Specifications

General IconGeneral
TypeOutdoor Fountain
Model NumberERPA2-8C*A
MaterialStainless Steel
Bowl ShapeRectangular
ADAYes
FinishStainless Steel
Mounting LocationWall
Number of Stations2
Bubbler MaterialStainless Steel
Freeze ResistantYes
Vandal ResistantYes
Drain1-1/2 in
OptionsBottle Filler

Summary

Important Installation Precautions

Electrical Grounding and Electrolysis Warning

Grounding can cause electrolysis; use plastic drain fittings to isolate the fountain from the building plumbing.

Installation Instructions

Chiller and Fountain Installation Steps

Install remote chiller, connect water supply, mount fountain to panel, and attach waste tube.

Water Pressure and Stream Adjustment

Ensure supply pressure is 20-105 PSIG; adjust stream height to hit basin approx. 6 1/2" from bubbler.

Panel Installation and Securing

Mount lower and bottom access panels securely using provided screws after installation.

Troubleshooting and Maintenance

Orifice and Stream Regulator Care

Clean mineral deposits from orifice with a small file; regulate stream height according to instructions.

Quick Connect Fitting Operation

Instructions for actuating water fittings by pushing in the collet to release the tube.

Bronzetone Model Cleaning Guidelines

Clean Bronzetone models with mild detergent or vinegar/water; rinse and dry.