EasyManua.ls Logo

Elkay SOFT SIDES ezH2O EZLMSN-EDFPVM214DK - User Manual

Elkay SOFT SIDES ezH2O EZLMSN-EDFPVM214DK
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
2000001510 (Rev. A - 03/24)
EZLMSN-EDFPVM214DK LZLMSN-EDFPVM214DK
Page 1
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only.
INSTALLER
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices
to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which
results in an “electrolysis” e󰀨ect occurring in the fountain. This may result in water which has a
metallic taste to it or has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation.
Any drain ttings provided by the installer should be made of plastic which will electronically isolate
the fountain from the remainder of the building’s plumbing circuits.
SOFT SIDES
®
Fountain with Vandal Resistant Bubbler
and Vandal Resistant Water Dispenser
INSTALLATION & USE MANUAL
EZLMSN-EDFPVM214DK
LZLMSN-EDFPVM214DK
(Shown with optional ACCESS12X19-75 access panel.)

Questions and Answers

Summary

Installer Safety and Guidelines

Required Tools and Materials

Required Special Tools

Lists any specialized tools needed for the installation process.

Additional Materials Not Included

Lists necessary materials not provided with the unit.

Catch Basin Waste Drain Installation

Fountain Installation and Initial Setup

Water Supply and Waste Connections

Connecting water supply lines and waste drain tubes to the fountain.

Bubbler Stream Height Adjustment

Guidance on adjusting the bubbler stream height for optimal performance.

Troubleshooting and Maintenance Guide

Orifice Assembly Troubleshooting

Addresses problems with mineral deposits on the orifice affecting water flow.

Stream Regulator Maintenance

Guidance on regulating water flow and replacement if necessary.

Quick Connect Fittings Operation and Maintenance

Instructions for the proper actuation and maintenance of water fittings.

Overview

The Elkay Soft Sides® Fountain is a drinking water dispenser designed for public and commercial use, featuring a vandal-resistant bubbler and water dispenser. This unit is intended for installation in various settings, providing convenient access to drinking water while incorporating features to enhance durability and ease of maintenance.

Function Description

The primary function of the Elkay Soft Sides® Fountain is to provide potable drinking water. It includes a traditional bubbler for direct drinking and a water dispenser, often referred to as a bottle filler, for filling bottles or cups. The design emphasizes vandal resistance, making it suitable for high-traffic areas where durability is a key concern. The unit is designed to connect to a building's cold water supply and drain system, ensuring a continuous supply of fresh water and proper waste disposal.

Usage Features

The fountain is designed for user-friendly operation. The bubbler provides a steady stream of water for direct drinking, activated by a push-button mechanism. The water dispenser/bottle filler allows users to easily fill their containers, typically activated by a separate button or sensor. The "Soft Sides" design likely refers to a smooth, contoured exterior that is aesthetically pleasing and potentially easier to clean.

Key usage features include:

  • Vandal-Resistant Design: Both the bubbler and the water dispenser are constructed with vandal-resistant components to withstand potential abuse and ensure longevity in public environments. This includes robust materials and secure fastenings.
  • ADA Compliance (with adjustments): The rough-in dimensions indicate that the unit can be installed to meet ADA (Americans with Disabilities Act) requirements, with a note to reduce height by 3 inches for children's ADA fountains. This ensures accessibility for a wide range of users.
  • Ground Fault Circuit Interrupter (GFCI) Requirement: New installations are required to use a GFCI, enhancing electrical safety for users.
  • Water Supply and Waste Connections: The unit connects to a 3/8" O.D. unplated copper tube for cold water supply and utilizes a 1-1/2" O.D. waste line for drainage. The quick connect fittings simplify the plumbing process, allowing for easy attachment and removal of tubing.
  • Stream Height Adjustment: The bubbler's stream height is factory set but can be adjusted to suit varying supply pressures. This adjustment is made via a screw on the regulator, accessible by removing the push button. Clockwise adjustment increases stream height, while counterclockwise movement lowers it, aiming for the stream to hit the basin approximately 6-1/2" from the bubbler.
  • Bottle Filler Operation: The bottle filler is activated by a push button. Initial dispenses might sputter due to air in the line, which will clear once the air is purged, resulting in a steady stream.
  • Optional Access Panel: The unit can be equipped with an optional access panel (ACCESS12X19-75), which may facilitate maintenance or provide a cleaner aesthetic.
  • Pressure Regulation: The product is designed to operate on 20-105 PSI supply line pressure. If the inlet pressure exceeds 105 PSI, a pressure regulator must be installed in the supply line to prevent damage and ensure proper operation. Operating outside this pressure range (below 20 PSI or above 105 PSI) is not covered under warranty.

Maintenance Features

The Elkay Soft Sides® Fountain is designed with maintenance in mind, incorporating features that simplify troubleshooting and part replacement.

Key maintenance features include:

  • Quick Connect Fittings: The use of quick connect fittings for water lines simplifies installation and future maintenance. To remove tubing, water pressure must be relieved, and the gray collar pushed in while pulling the tubing. To insert, the tube is pushed straight into the fitting until it reaches a positive stop.
  • Drain Installation for Overflow Prevention: The installation of a drain basin is highly recommended to prevent basin overflow. The process involves removing the drain basin, drilling a hole, installing a strainer with an O-ring, and connecting it to a drain adapter and flexible drain hose. Plastic drain fittings are recommended to electronically isolate the fountain from the building's plumbing circuits, preventing "electrolysis" effects that can cause metallic taste or increased metallic content in the water.
  • Orifice Assembly Maintenance: Mineral deposits on the orifice can cause water flow to spurt or not regulate. These deposits can be removed by carefully poking with a small round file (not over 1/8" diameter) or a small diameter wire. A caution is provided against filing or cutting the orifice material.
  • Stream Regulator Replacement: If the orifice is clean but flow regulation is still an issue, the stream regulator may need replacement. The parts list provides the correct regulator part number for this purpose.
  • Filter Head Assembly: The unit can be equipped with a WaterSentry® Plus filter, which requires periodic replacement. The filter head assembly (Part No. 51300C or 51469C) is designed for easy replacement.
  • Component Accessibility: The design allows for access to internal components for servicing. For example, the push button and regulator are accessible for stream height adjustments. The bottom cover plate and back panel can be removed for access to the internal plumbing and electrical connections.
  • Leak Checks: After installation and any maintenance, it is crucial to turn on the water supply, bleed any trapped air from the system, and re-check for any water leaks to ensure proper sealing and operation.
  • Troubleshooting Guidance: The manual provides specific troubleshooting steps for common issues like sputtering water (due to air in the line) and irregular water flow (due to mineral deposits or regulator issues).

Overall, the Elkay Soft Sides® Fountain is a robust and accessible drinking water solution, designed for public use with an emphasis on durability, ease of installation, and straightforward maintenance.

Elkay SOFT SIDES ezH2O EZLMSN-EDFPVM214DK Specifications

General IconGeneral
ADA CompliantYes
ModelEZLMSN-EDFPVM214DK
MaterialStainless Steel
bubbler activationPush Button
Mounting OptionWall
Mounting TypeWall Mount

Related product manuals