Page 1
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only.
INSTALLER
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices
to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which
results in an “electrolysis” effect occurring in the fountain. This may result in water which has a
metallic taste to it or has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation.
$Q\GUDLQ¿WWLQJVSURYLGHGE\WKHLQVWDOOHUVKRXOGEHPDGHRIplastic which will electronically isolate
the fountain from the remainder of the building’s plumbing circuits.
LZWS-EDFPBM117KEZWS-EDFPBM117K
SWIRLFLO
®
Fountains with FLEXI-GUARD
®
and ezH2O
®
Bottle Filler
INSTALLATION & USE MANUAL
Question and Answer IconNeed help?

Do you have a question about the Elkay EZWS-EDFPBM117K and is the answer not in the manual?

Elkay EZWS-EDFPBM117K Specifications

General IconGeneral
BrandElkay
ModelEZWS-EDFPBM117K
CategoryOutdoor Fountain
LanguageEnglish

Summary

INSTALLER GUIDELINES

Installation Safety Warnings

Important safety notes including caution and warnings for installers.

Grounding and Electrolysis Note

Explains potential electrolysis effect from grounding and preventative measures.

REQUIRED TOOLS AND MATERIALS

Special Tools List

Lists specialized tools necessary for the installation process.

Included Materials List

Lists additional materials not provided with the unit.

CONTROL BOARD SETTINGS

Verify Software and Access Programming

Steps to check software version and locate the programming button.

Reset Filter Monitor

Procedure to reset the filter monitor indicator light.

Configure Sensor Range and Unit Type

Adjust IR sensor range and set unit type (refrigerated/non-refrigerated).

Bottle Count and Filter Capacity Settings

How to reset bottle count and set filter capacity.

Electrical Diagram

Installation Package Contents

TROUBLESHOOTING AND MAINTENANCE

Orifice Assembly Maintenance

Guidance on cleaning mineral deposits from the orifice for proper flow.

Water Fitting Connection and Maintenance

Instructions for connecting/disconnecting water fittings and troubleshooting flow.

MOUNTING FRAME INSTALLATION

Wall Opening and Reinforcement

Specifies wall opening dimensions and reinforcement requirements for frame mounting.

Frame Assembly and Securing

Steps for assembling the mounting frame and securing it to the wall.

Mounting Frame Wiring

Instructions for making electrical connections to the mounting frame.