ems controllers then copy the pattern learnt from day 1 to the remaining six days of the self-learning matrix, as shown in the
following example matrix:
ems controllers with a one day learning period start switching to the saving mode on the second day, (second 24 hours), if
there are sufficient saving (0) periods.
ems controller then continue to update the self-learning matrix as follows:
l For periods set to ready (2), if no activity is detected change to monitor (1). Otherwise, keep the period set to ready (2).
l For periods set to saving (0), if activity is detected change to monitor (1). Otherwise, keep the period set to monitor (0).
For example, the self-learning matrix shows that the outlet is open for longer on day 2 than day 1.
Therefore, the ems controller has changed the state of the periods that were set to saving (0) to monitor (1) as shown in the
following example matrix.
At the end of week 1, the ems controller has updated the self-learning matrix for the outlet activity pattern as shown below.
Note that differences for activity patterns learnt on day 2 take two weeks to be implemented. Therefore, 1 day learning peri-
ods are recommended only for outlets with regular patterns every day of the week.
ems55advanced and ems55Radvanced / General Use
32 of 84

Table of Contents

Other manuals for Elstat ems55advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elstat ems55advanced and is the answer not in the manual?

Elstat ems55advanced Specifications

General IconGeneral
BrandElstat
Modelems55advanced
CategoryController
LanguageEnglish

Related product manuals