EasyManuals Logo

Elstat ems75sz User Manual

Default Icon
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
EMS controllers then update the self-learning matrix depending on how much activity is detected in
each 30 minute period as follows:
l If the EMS controller detects activity during a 30 minute period, the EMS controller changes the state from mon-
itor (1) to ready (2)
l If the EMS controller does not detect activity, the EMS controllers changes the state from monitor (1) to
saving (0).
Note:
l The amount of activity required to change the state frommonitor (1) to ready (2) depends on the setting of the
activity frequency (AF) parameter.
Therefore, at the end of day 1, (first 24 hours), the EMS controller has set all the 30 minutes to ready
(2) or saving (0) depending the outlet activity pattern as shown in the example matrix:
EMS controllers then copy the pattern learnt from day 1 to the remaining six days of the self-learning
matrix, as shown in the following example matrix:
42 of 86
27 February 2014

Table of Contents

Other manuals for Elstat ems75sz

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elstat ems75sz and is the answer not in the manual?

Elstat ems75sz Specifications

General IconGeneral
BrandElstat
Modelems75sz
CategoryController
LanguageEnglish

Related product manuals