6.3.22 High voltage (HI)
Display
Description
Denes the maximum voltage allowed before switching o the compressor. The high
voltage (HI) values are 10% of the actual line in voltages (see table below).
Considerations
Must not be used with an external voltage stabiliser
Must only be used with the following Elstat supplied power supply modules (PSM):
30001-0102 or 30002-0102
Global default 0 (disabled)
110-120V line 220-240V line
voltage HI voltage HI
Disabled 0 220 22
120 12 230 23
130 13 240 24
140 14 250 25
260 26
270 27
Note: Voltage measurement is accurate to typically ±10%
Caution
Voltage management operation, as described above, will only operate reliably when
power is supplied by the following power supply modules: Elstat Sub Zero PSM part
number- 30001-0102, (120V) variant, or 30002-0102, (240V) variant.
If Elstat ems 75 SZ PSM part number 3101-0102, (120V) variant, or part number 33102-
0102, (240V) variant, are used then the voltage management operation and the alarms
that it will produce cannot be relied upon to accurately reect the state of the mains
power supply, and subsequent damage may occur to the cooler.
High voltage protection is not calibrated and actual performance can be inuenced by
several factors. Therefore, total protection cannot be guaranteed.