CMS200 Product Manual, Issue 6
www.nexo.com Page 53
6.3.21 Low voltage (LO)
Display
Description
Denes the minimum voltage allowed before switching o the compressor. The low
voltage (LO) values are 10% of the actual line in voltages (see table below).
Considerations
Must not be used with an external voltage stabiliser
Must only be used with the following Elstat supplied power supply modules (PSM):
30001-0102 or 30002-0102
Global default 0 (disabled)
110-120V line 220-240V line
voltage LO voltage LO
Disabled 0 170 17
80 8 180 18
90 9 190 19
100 10 200 20
110 11 210 21
Note: Voltage measurement is accurate to typically ± 10%
Caution
Voltage management operation, as described above, will only operate reliably when
power is supplied by the following power supply modules: Elstat Sub Zero PSM part
number- 30001-0102, (120V) variant, or 30002-0102, (240V) variant.
If Elstat ems75 SZ PSM part number 3101-0102, (120V) variant, or part number 33102-
0102, (240V) variant, are used then the voltage management operation and the alarms
that it will produce cannot be relied upon to accurately reect the state of the mains
power supply, and subsequent damage may occur to the cooler.
Low voltage protection is not calibrated and actual performance can be inuenced by
several factors. Therefore, total protection cannot be guaranteed.