Model 2000 Flow Computer Instruction Manual
2.0 GENERAL DESCRIPTION
Model 2000 issue 21 Page No
9
2.2.6. MAIN MENU FUNCTION Totals
This menu item is a read only display and when selected will show all the pages of flow totals available in this machine these
will include:-
For Turbine Machines
+Vbu Uncorrected Volume from Meter “Un-haltable” i.e. always counts
+Vb Uncorrected Volume from Meter
+Vbc Uncorrected Volume corrected for meter non-linearity
+Vbcu Uncorrected Volume corrected for meter non-linearity “Un-haltable” i.e. always counts
+Vb Uncorrected Volume from Monitor
+Vn Corrected Volume
+Vnu Corrected Volume from Meter “Un-haltable” i.e. always counts
+M Mass
+Mu Mass “Un-haltable” i.e. always counts
+E Energy
+Eu Energy “Un-haltable” i.e. always counts
For Ultrasonic Machines
+Vbu Uncorrected Volume from Meter “Un-haltable” i.e. always counts
+Vb Uncorrected Volume from Meter
+Vbcu Uncorrected Volume corrected for meter non-linearity “Un-haltable” i.e. always counts
+Vb Uncorrected Volume from Monitor
+Vn Corrected Volume
+Vnu Corrected Volume from Meter “Un-haltable” i.e. always counts
+Vdry Corrected Volume of dry gas
+Vdryu Corrected Volume of dry gas “Un-haltable” i.e. always counts
+M Mass
+Mu Mass “Un-haltable” i.e. always counts
+E Energy
+Eu Energy “Un-haltable” i.e. always counts
For Wet Gas Venturi machines
+Mguc Mass gas from Venturi no correction for wet gas
+Mgc Mass gas from Venturi corrected for wet gas
+Mlc Mass liquid corrected
+Ngl Line Volume of gas
+Ngb Base Volume of gas
+Nll Line Volume of Liquid
+Nlb Line Volume of Liquid
+Mw Mass of Water
+Mc Mass of Condensate
All the above Venturi Totals are also available in un-haltable versions
For Wet Gas Venturi type 2 machines
+Mguc Mass gas from Venturi no correction for wet gas
+MgS Mass saturated gas from Venturi corrected for wet gas
+MgD Mass dry gas from Venturi corrected for wet gas
+ML Mass liquid corrected
+MTP Mass two phase product including Water
+MC Mass condensate liquid corrected
+MW Mass Water liquid corrected
+MM Mass Methanol liquid corrected
+Mhc Mass Hydro Carbon corrected
+VnG Standard Volume of gas
+VnC Standard Volume of condensate
+VnW Standard Volume of Water
+E Energy
All the above Venturi Totals are also available in un-haltable versions

Table of Contents