Model 2000 Flow Computer Instruction Manual
2.0 GENERAL DESCRIPTION
Model 2000 issue 21 Page No
11
This menu item is a read only display and when selected will show the status of any serially connected Liquid Coriolis Meter
and Meter data, this page will only be shown if a Coriolis M2000 type has been selected using the M2000 windows software.
The data items available are as follows:-
Current read Status Reading Data or Waiting
Last read Status OK or Comms Problem
CM Status Meter Status Information
CM Mass Meter Mass flow rate in kg/hr
CM Density Meter Density in kg/m3
CM Volume Meter Volume flow rate in m3/day
CM temperature Meter Temperature
CM pressure Meter Pressure
CM Mass and Volume Totals
The items will be divided into pages with a maximum of four items per page.
2.2.9. MAIN MENU FUNCTION Grab Sampler
This menu item is a read only display and when selected will show a sub menu as below:-
Sampler 1
Sampler 2
Sampler 1 shows the status and operational state of Liquid Grab Sampler 1 and Sampler 2 shows the same information for
Liquid Grab Sampler 2. The data items available are as follows:-
Sampler current and remaining Volume in cc
Sampler Volume in m3
Required, current and remaining Sampler pulses to fill the can
Sampler Rate in cc/m3
Can fill level in %
Grab Sampler Status
The items will be divided into pages with a maximum of four items per page.
2.2.10. MAIN MENU FUNCTION Chromatograph
This menu item is a read only display and when selected will show the status of any connected Gas Chromatograph, this
page will only be available if a gas chromatograph has been set up using the M2000 windows software. The data items
available are as follows:-
Current read Status Reading Data or Waiting
Last read Status OK or Comms Problem
Chr Stream Number
Chr Analysis N/A, Analysis or Calibrate
Chr State N/A, Idle, Analysis or Calibrate
Chr Status 1 16 bits of Status
Chr Status 2 16 bits of Status
The items will be divided into pages with a maximum of four items per page. See page 75 for details of Gas Chromatographs
that are supported and the Modbus Communication addresses that are read by the Model 2000. The above is a typical
example so not all the above data items may be available for all types of Gas Chromatograph.
2.2.11. MAIN MENU FUNCTION Station Controller
This menu item is a read only display and when selected will show all the pages of data relating to the set up of the Station
Controller. This will include:-
Number of Connected units and their communication ids.
Current operating Status of Read and Writes to those units.
2.2.12. MAIN MENU FUNCTION PID Controller
This menu item is a read only display and when selected will show all the pages of available information that relate to the
Proportional, Integral and Derivative control outputs in this machine.