Tasks to replace an SP
EMC VNXe3100/VNXe3150 — Replacing a Storage Processor 7
4. Slide the BBU into the canister on the replacement SP until the release tab catches.
5. Attach the BBU cable connector to the replacement SP CPU board.
Task 6: Transfer the I/O module or filler module
Remove the I/O module (or filler module) from the faulted SP and install it in the
replacement SP:
1. Carefully lift the blue latch on the faulted processor board until it ejects the I/O or filler
module from the connector.
2. Lift the module out and away from the canister.
3. Angle the I/O module slightly so it fits into the canister on the replacement SP and
align it with the blue alignment pins.
CL4684
CL4685
2
1
CL4688