SOLENOID DRIVEN METERING PUMPS
WITH DIAPHRAGM
EN
VMS MF - VMSA MF
OPERATING MANUAL
VMSA MF
VMS MF

Questions and Answers

  • D
    Daniel LopezAug 6, 2025
    What to do if my Emec Pump is not dosing but the solenoid is operating?
    • J
      jasonjamesAug 6, 2025
      If your Emec Pump isn't dosing, but the solenoid is working, the issue might be a blocked foot filter. Try cleaning it. Another cause could be an empty suction hose, in which case you should prime the pump again. Air bubbles in the hydraulic circuit could also be the reason, so inspect the valves, hoses, and fittings. Lastly, if the product you're dosing is generating gas, turn the discharge knob to release the air or switch to a self-venting pump head.
  • T
    Tony FullerAug 14, 2025
    Why Emec VMS MF doesn’t turn on?
    • A
      Amber EdwardsAug 14, 2025
      If your Emec Pump doesn’t turn on, first ensure it’s properly connected to the main power supply. If it is, the pump's protection fuse might be broken and needs replacement. In the event that the fuse is intact, the pump’s main board could be faulty and require replacement.
  • N
    nicholas94Aug 20, 2025
    What to do if Emec Pump is not dosing and solenoid isn’t operating or slightly operating?
    • M
      mshawAug 20, 2025
      If your Emec Pump is not dosing and the solenoid isn’t operating (or is operating slightly), crystals might be present inside the valves. Check the valves and try dosing 2-3 liters of normal water, and consider changing the valves. Also, the injection valve could be obstructed and needs replacement.
  • N
    Nicole ParkerAug 27, 2025
    Why does my Emec Pump display “ER- ROR MEM” or “ERROR DATA”?
    • J
      Justin FischerAug 28, 2025
      If your Emec Pump's display shows “ER- ROR MEM” or “ERROR DATA”, then in the case of “ERROR MEM” it indicates an error in data storage, and it is necessary to reload the pump’s default data. If the display shows “ERROR DATA”, then there is an error in data setting, so check the values set. If they are correct, but the message still appears, the pump is underdimensioned.

Summary

OPERATING MANUAL

VMS MF - VMSA MF Product Series

Overview of VMS MF and VMSA MF pump series.

Solenoid Driven Metering Pumps

Description of solenoid-driven metering pump technology.

GENERAL SAFETY GUIDELINES

Safety Information and CE Compliance

General safety instructions and CE directives compliance.

Safety Message Icons

Explanation of safety icons used in the manual.

PURPOSE OF USE AND SAFETY

Pump Application and Pre-Operation Safety

Intended use of the pump and essential pre-operation safety checks.

ENVIRONMENTAL SAFETY

Recycling, Waste, and Labels

Guidelines for pump recycling, waste disposal, and labels.

1. Introduction

Pump Capacity and Working Modes Overview

Details on pump capacity, flow rate, and available working modes.

2. Unpacking

Package Contents and Component Legend

List of items included in the pump package and component legend.

3. Pumps Description

Pump Component Identification

Identification and description of key pump components.

4. Before to Install Warnings

Installation Safety Precautions

Critical safety guidelines to follow before pump installation.

5. Installation Draw

Installation Diagram and Components

Diagram illustrating pump installation with component labels.

6. Hydraulic Installation

Hydraulic Connections Procedure

Step-by-step guide for making hydraulic connections.

Assembling Foot Filter with Level Probe

Foot Filter, Level Probe, and Hose Assembly

Assembly instructions for foot filter, level probe, and hoses.

Discharge Hose

Discharge Hose Connection

Procedure for connecting the discharge hose.

Self-Venting Pump Head

Self-Venting Pump Head Notes

Notes and considerations for self-venting pump heads.

7. Electrical Installation

Electrical Connection Requirements and Warnings

Requirements and warnings for electrical connections.

Pulse Emitter Water Meter with Hall Effect

External Signal Wiring and Mode Restrictions

Wiring for external signals and mode restrictions for Hall effect.

8. Basic Settings

LCD Display, Keyboard, and Menu Navigation

Overview of the LCD display, keyboard functions, and menu navigation.

Settings Management and Password

Procedures for managing settings, saving changes, and password protection.

9. Priming

Priming Procedure Steps

Detailed steps for the pump priming process.

10. Pumps Functions Summary

Working Mode Information and Alarms

Summary of pump functions, working modes, and alarm indicators.

Quick Guide - Main Menu

Mode Selection (Prog [1])

Guide to selecting operating modes via the main menu.

Setup Options (Prog [2])

Guide to configuring pump settings via the setup menu.

Statistics Menu (Prog [3])

Guide to accessing and managing pump statistics.

15. Setup

Initial Pump Setup and Calibration

Procedures for initial pump setup and calibration.

Water Meter and Pulses Timeout Settings

Configuring Water Meter Input

Configuration for water meter input.

Pulses Timeout Configuration

Configuration for timeout of external pulses.

Unit Change and Startup Delay Setup

Changing Measurement Units

Instructions for changing measurement units.

Configuring Startup Delay Timer

Procedure for configuring the startup delay timer.

Password Setup

Protecting Setup Menu Access

Procedure for setting and protecting the pump's password.

16. Load Default and Reset Password Procedure

Default Settings and Password Reset

Procedures for loading default settings and resetting the password.

17. Working Procedure Setup

Working Mode Configuration Overview

Overview of different working mode configurations.

Working Modes Configuration Details

PERC Mode Configuration Details

Detailed configuration for PERC mode.

MLQ Mode Configuration Details

Detailed configuration for MLQ mode.

BATCH Mode Configuration Details

Detailed configuration for BATCH mode.

VOLT Mode Configuration Details

Detailed configuration for VOLT mode.

mA Mode Configuration Details

Detailed configuration for mA mode.

18. CONSTANT Working Mode

Constant Mode Parameters

Parameters required for configuring the CONSTANT working mode.

19. DIVIDE Working Mode

DIVIDE Mode Parameters and Formula

Parameters and formula for configuring the DIVIDE working mode.

20. MULTIPLY Working Mode

MULTIPLY Mode Parameters and Formula

Parameters and formula for configuring the MULTIPLY working mode.

21. PPM Working Mode

PPM Mode Parameters and Notes

Parameters and notes for configuring the PPM working mode.

22. PERC Working Mode

PERC Mode Parameters and Notes

Parameters and notes for configuring the PERC working mode.

23. MLQ Working Mode

MLQ Mode Parameters and Notes

Parameters and notes for configuring the MLQ working mode.

24. BATCH Working Mode

BATCH Mode Configuration and Notes

Configuration and notes for the BATCH working mode.

25. VOLT Working Mode

VOLT Mode Configuration and Error Handling

Configuration and error handling for VOLT mode.

23. mA Working Mode

mA Mode Configuration and Error Handling

Configuration and error handling for mA mode.

24. STATISTICS Management

Accessing and Resetting Statistics

Guide to accessing and resetting pump statistics.

25. Troubleshooting

Common Pump Problems and Solutions

Troubleshooting guide for common pump issues and their solutions.

26. Fuse and Main Board Replacement

Fuse and Main Board Replacement Procedures

Step-by-step guide for replacing fuses and main boards.

27. Main Board

Main Board Schematics and Connections

Schematics and connection details for the pump's main board.

A. Appendix: Maintenance

Maintenance Schedule and Operator Safety

Maintenance schedule, operator protection, and safety procedures.

Shutdown Procedure

Shutdown Procedure and Safety Precautions

Procedure for safely shutting down the pump.

Appendices: Technical Info, Materials, Curves, Dimensions

Technical Features and Specifications

Details on technical features and pump specifications.

Material and Chemical Compatibility

Information on materials used and chemical compatibility.

Delivery Curves

Graphs showing pump delivery performance under various conditions.

Hose Resistance Data

Table detailing hose resistance to pressure and temperature.

Pump Dimensional Data

Table listing pump dimensions in mm and inches.

Product Service Repair Form

Repair Form Details and Sections

Form for documenting product service and repair information.

Emec VMS MF Specifications

General IconGeneral
Protection ClassIP65
Power Supply230V 50/60Hz
Material (Pump Head)PP, PVDF, SS316
Material (Diaphragm)PTFE
ControlManual
MaterialPP, PVDF, SS316