Introduction
Parameter
x.00
Parameter
description format
Keypad and
display
Serial
communications
CT Modbus
RTU
PLC Ladder
programming
CTSoft Menu 0
Advanced parameter
descriptions
Menu 15
I/O options
Commander SK Advanced User Guide 173
Issue Number: 9
Figure 10-44 Menu 15A logic diagram*
* x in the parameter boxes represents Menu 15 (i.e. x.04 = Pr 15.04)
15.54 Drive encoder position
0 to 65535 (1/2
16
ths of a
revolution)
BW
15.55 Drive encoder speed feedback
-32000 to +32000 rpm BW
15.56 Maximum drive encoder reference
0 to 32000 rpm 1500 BR
15.57 Drive encoder reference level
-100% to +100% BW
15.58 Drive encoder reference scaling
0.000 to 4.000 1.000 BR
15.59 Drive encoder reference destination Pr 0.00 to Pr 21.51 Pr 0.00 Drive reset
15.60 Encoder reset
OFF(0) or On(1) OFF(0)
Encoder only
13ms. All I/O
routed 30ms
Parameter Range Default Setting Update Rate
T5
x.04
Monitor
x.14
Invert
x.24
Destination
0.00
21.51
Default
destination
Pr 0.00
T6
x.05
Monitor
x.15
Invert
x.25
Destination
0.00
21.51
Default
destination
Pr 0.00
T7
x.06
Monitor
x.16
Invert
x.26
Destination
0.00
21.51
Default
destination
Pr 0.00
x.27
0.00
x.17
Invert
Default
source
Pr 0.00
21.51
0V
x.07
Monitor
T21
T23
Relay
source
XX
XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
XX
XX

Table of Contents