100-214-251 REV. 05 21
This multi-turn control is calibrated in color rings, visible in slots.
4 Autotune Label Refer to Section 7.4.1 Manual Tuning
5 Front Panel Displays Refer to next Section
6 Stroke Indicator
Provides a quick method of determining relative
carriage travel during a weld cycle; indicates 0-4 in
0-100 mm).
7 Trigger Pressure Control
Selects dynamic triggering pressure; calibrated 1-
24 in half-steps/48 detents corresponding to a
force range of 15-200 lbs/67-890 N.
8 Carriage Door
Provides access to the converter-booster-horn
stack; secured by 4 captive hex screws.
9
Mechanical Stop
Locking Nut
Locks the mechanical stop to desired depth.
10 Mechanical Stop
Limits the distance the carriage travels to prevent
horn from contacting the fixture or nest when no
workpiece is in place; adjustment is approximately
0.04 in/1 mm per rotation.
Table 2.1 Front Panel Controls IW
Item Name Function
100-214-251 IWoper.book Page 21 Friday, June 16, 2017 4:12 PM