100-214-251 REV. 05 87
6.1.2.2Collapse Distance Mode, IW+ only
Use Collapse Distance mode to control material displacement. For example, when sealing
around a filter border, and you need a hermetic seal.
Collapse Distance mode can be set with Time and both Collapse or Absolute limits.
+ Limit Monitors Yes Yes Yes
- Limit Monitors Yes No Yes
NOTICE
Safety limits, if reached, will terminate Weld Time.
Table 6.4 Time Mode Parameters, IW+ only
Parameter
Control and/or
Monitor
Can be Disabled Safety Limits Alarm
NOTICE
In Collapse or Absolute Distance Modes the weld time parameter acts as an overriding
condition. Ensure Time is setup to allow for the collapse or absolute distances to be
attained during a weld.
100-214-251 IWoper.book Page 87 Friday, June 16, 2017 4:12 PM