Copeland Scroll
Outdoor Refrigeration Unit
Installation and reference manual
Models:
XFAL, XFAM, XFAP
1.5 to 6 HP

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Emerson Copeland Scroll XFAM Series and is the answer not in the manual?

Emerson Copeland Scroll XFAM Series Specifications

General IconGeneral
BrandEmerson
ModelCopeland Scroll XFAM Series
CategoryHeat Pump
LanguageEnglish

Summary

Safety Instructions

Safety Icon Explanation

Explains the meaning of safety icons like Danger, Warning, and Caution used in the manual.

General Safety Warnings

Electrical Shock Hazard

Details precautions against electrical shock during servicing and operation.

Pressurized System Hazard

Outlines risks associated with pressurized refrigerant and oil systems.

Burn Hazard

Provides warnings and precautions related to touching hot compressor components.

Compressor Handling Safety

Specifies safe practices for lifting and moving compressors.

4. Installation;Piping Instructions

5. Quick Setup Guide

6.10. Alarm Menu

Accessing and Navigating Alarm Menu

Details how to enter, view, and scroll through stored alarms.

6.11. How to Program a HOT-KEY From the Controller (UPLOAD)

6.12. How to Program a Controller Using a HOT-KEY (Download)

6.18. Suction Pressure Control

6.19. Fan Control

6.20. Defrost Controls

Set Defrost Parameters and Schedule

Guides on setting defrost cycle intervals, duration, and mode.

6.21. Enhanced Vapor Injection (EVI)

EVI System Operation

Explains how the EVI system regulates vapor injection for performance optimization.

Low Temp EVI Discharge Line Temp Protection

Describes the DLT protection mode for EVI systems and error handling.

6.21.1. Low Temp EVI Discharge Line Temperature Protection Error Handling

DLT Sensor Failure Handling

Explains how the EVI system operates when the DLT sensor fails.

6.21.2. EVI System Checks (XFAL units only)

6.21.3. Constant Liquid Temperature Mode For Low Ambient EVI Injection

6.22. Medium Temperature DLT Protection

DLT Protection for Medium Temp Units

Explains liquid injection for preventing compressor overheat in medium temp units.

DLT Protection Error Handling

Details error handling procedures for DLT sensor failures in medium temp units.

6.23. Over-Current Protection

Over-Current Protection Logic

Describes how the controller detects and responds to over-current conditions.

6.24. Incorrect Phase Sequence Protection (3 Phase Only)

Phase Sequence Error Handling

Explains how the controller detects and reacts to incorrect phase sequences.

6.25. Loss of Phase Protection - Current (3 Phase Only)

Loss of Phase Protection Logic

Details the controller's response to missing phase supplies in 3-phase systems.

6.26. Open Run Circuit (Single Phase Only)

Open Run Circuit Detection

Describes the controller's detection of an open run circuit in single-phase operation.

6.27. Open Start Circuit (Single Phase Only)

Open Start Circuit Detection

Explains how the controller detects an open start circuit in single-phase operation.

6.28. Over;Under Voltage Protection

Voltage Protection Logic

Details the controller's response to over or under voltage conditions.

6.29. Phase Imbalance (3 Phase Only)

Phase Imbalance Detection

Describes how the controller detects and handles phase imbalances.

6.30. Compressor Internal Thermal Protection

Thermal Protector Trip Detection

Explains how the controller detects compressor internal thermal protector trips.

6.31. Fixed High Pressure Control

High Pressure Switch Operation

Details the function of the nonadjustable high pressure switch.

6.33. Anti-Flood Back Warning

Liquid Flood Back Warning Logic

Describes the logic for detecting and warning about liquid flood back.

6.34. High Condensing Temperature Warning

High Condensing Temp Warning

Explains the warning condition for high condensing temperatures.

8. Physical and Installation Requirements

9. Wiring Diagrams

Sensor Connections

Low Temp 1-Phase 2.0-3.5 HP 1 Condenser Fan Wiring Diagram

Low Temp 1-Phase 4-5 HP 2 Condenser Fans Wiring Diagram

Medium Temp 1-Phase 1.5-3 HP 1 Condenser Fan Wiring Diagram

Medium Temp 3-Phase 1.5-3 HP 1 Condenser Fan Wiring Diagram

Medium Temp 3-Phase 4.5-6 HP 2 Condenser Fans Wiring Diagram

Low Temp 3-Phase 2-3 HP 1 Condenser Fans Wiring Diagram

Low Temp 3-Phase 4-6 HP 2 Condenser Fans Wiring Diagram

Medium Temp 1-Phase 4.5-5 HP 2 Condenser Fans Wiring Diagram

11. Alarm Codes

Alarm Codes and Descriptions

Lists alarm codes, their descriptions, alarm levels, and diagnostic resolutions.

Alarm Codes

Over Voltage;Current;Phase Alarms

Details alarm and lockout codes for voltage, current, and phase issues.

Compressor Trip and High Pressure Alarms

Lists alarms related to compressor protection, high pressure, and DLT.

12. Sensor Values

13. Parameters

Compressor Programming Parameters

Details parameters for compressor cut-in/out pressure and refrigerant selection.

Compressor Safety Parameters

Compressor Safety Settings

Details parameters for output delay, probe fault times, and minimum off time.

Compressor Protection Parameters

Details parameters for over-current trips, loss of phase, and compressor trips before lockout.