Digitax ST User Guide 187
Issue: 5
Et External trip from input on terminal 31
6
Check terminal 31 signal
Check value of Pr 10.32
Enter 12001 in Pr xx.00 and check for parameter controlling Pr 10.32
Ensure Pr 10.32 or Pr 10.38 (=6) are not being controlled by serial comms
HF01 Data processing error: CPU address error
Hardware fault - return drive to supplier
HF02 Data processing error: DMAC address error
Hardware fault - return drive to supplier
HF03 Data processing error: Illegal instruction
Hardware fault - return drive to supplier
HF04 Data processing error: Illegal slot instruction
Hardware fault - return drive to supplier
HF05 Data processing error: Undefined exception
Hardware fault - return drive to supplier
HF06 Data processing error: Reserved exception
Hardware fault - return drive to supplier
HF07 Data processing error: Watchdog failure
Hardware fault - return drive to supplier
HF08 Data processing error: Level 4 crash
Hardware fault - return drive to supplier
HF09 Data processing error: Heap overflow
Hardware fault - return drive to supplier
HF10 Data processing error: Router error
Hardware fault - return drive to supplier
HF11 Data processing error: Access to EEPROM failed
Hardware fault - return drive to supplier
HF12 Data processing error: Main program stack overflow
Hardware fault - return drive to supplier
HF13 Data processing error: Software incompatible with hardware
Hardware or software fault - return drive to supplier
HF17 Multi-module system thermistor short circuit or open circuit
217 Hardware fault - return drive to supplier
HF18 Multi-module system interconnect cable error
218 Hardware fault - return drive to supplier
HF19 Temperature feedback multiplexing failure
219 Hardware fault - return drive to supplier
HF20 Power stage recognition: serial code error
220 Hardware fault - return drive to supplier
HF21 Power stage recognition: unrecognized frame size
221 Hardware fault - return drive to supplier
HF22 Power stage recognition: multi module frame size mismatch
222 Hardware fault - return drive to supplier
HF23 Power stage recognition: multi module voltage rating mismatch
223 Hardware fault - return drive to supplier
HF24 Power stage recognition: unrecognized drive size
224 Hardware fault - return drive to supplier