190 Digitax ST User Guide
Issue: 5
rS Failure to measure resistance during autotune
33 Check motor power connection continuity
SAVE.Er User save parameters in the EEPROM are corrupt
36
Indicates that the power was removed when user parameters were being saved.
The drive will revert back to the user parameter set that was last saved successfully.
Perform a user save (Pr xx.00 to 1000 or 1001 and reset the drive) to ensure this trip does not occur the next time the drive is
powered up.
SCL Drive RS485 serial comms loss to remote keypad
30
Re-instal the cable between the drive and keypad
Check cable for damage
Replace cable
Replace keypad
SLX.dF Solutions Module slot X trip: Solutions Module type installed in slot X changed
204,209 Save parameters and reset
Trip Diagnosis