How to See the MIN Temperature MAX and MIN Temperature Memorization • 5
5MAX and MIN
Temperature
Memorization
5.1. How to See the MIN
Temperature
1. Press and release the DOWN arrow key.
2. The Lo message will be displayed followed by the
minimum temperature recorded.
3. By pressing the DOWN arrow key again or by wait-
ing 5 seconds, the normal display will be restored.
5.2. How to See the MAX
Temperature
1. Press and release the UP arrow key.
2. The Hi message will be displayed followed by the
maximum temperature recorded.
3. By pressing the UP arrow key again or by waiting 5
seconds, the normal display will be restored.
5.3. How to Reset MAX and
MIN Temperature
Recorded
1. Press and hold the SET key for more than 3 seconds
while the maximum or minimum temperature is dis-
played. (rSt message will be displayed)
2. To confirm the operation, the rSt message starts
blinking and the normal temperature will be dis-
played.