168
Epsilon Eb and E Series EN Drives Reference Manual
APS Input Specification
Caution
Do not wire AC line power into the APS input. Doing so will damage the drive.
Warning
Do not open the APS jumper access until at least 6 minutes has elapsed after the main AC
power has been removed from the L1 and L2 terminals.
Note
Connecting 24V common on the APS to chassis ground reduces offset voltage in the
Analog Diagnostics Outputs.
Voltage Range Current Inrush Current
18-30 VDC
0.5 A maximum
0.7 A peak
( 0.4 A maximum
0.76 A peak if external
encoder is not used )
80 A for 1 ms if not limited by power
supply
Drive Logic with Motor Encoder Only Add for Master Encoder Other Dependancies
APS Applied
Voltage
18 24 28 18 24-28
Add 10% per axis for fewer
than 4 axis on same A.P.S.
power supply.
Current Draw per
drive
(mA RMS)
550 400 360 110 75
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com