Installation
Figure 104: Multiple APS Wiring Diagram
Motor Power Wiring
MG and NT Motors are equipped with up to three male MS (Military Style) connectors, one
for stator connections, one for encoder connections and one for the brake (if so equipped).
Stator connections from the drive to the motor are made with the CMDS or CMMS cable have
a female MS style connector on the motor end and four individual wires and shield that
connect to the motor power connector on the bottom of the drive.
Note
The motor ground wire and shields must be run all the way back to the amplifier terminal
and must not be connected to any other conductor, shield or ground.
Front ViewFront View
24 VDC
J1
1 A
Fuse
J1
1 A
Fuse
+
-
Single point PE
ground