Introduction and Specifications
September 2013
1-9
Table 1-5. Hazardous Area Classifications—FM (United States)
Certification
Body
Type Certification Obtained Entity Rating Temperature Code
Enclosure
Rating
FM
DVC60x0
DVC60x0S
(x = 1,2,3)
IS Intrinsically Safe
Class I,II,III Division 1 GP A,B,C,D,
E,F,G per drawing GE42819
Natural Gas Approved
Vmax = 30 VDC
Imax = 226 mA
Ci = 5 nF
Li = 0.55 mH
Pi = 1.4 W
T5(Tamb ≤ 80C)
T6(Tamb ≤ 75C)
Type 4X, IP66
Single Seal Device
XP Explosion-proof
Class I Division 1 GP B,C,D
NI Non-incendive
Class I Division 2 GP A,B,C,D
DIP Dust Ignition-proof
Class II, III Division 1 GP E,F,G
S Suitable for Use
Class II, III Division 2 GP F,G
Natural Gas Approved
− − −
T5(Tamb ≤ 80C)
T6(Tamb ≤ 75C)
Type 4X, IP66
Single Seal Device
DVC6005
IS Intrinsically Safe
Class I,II,III Division 1 GP A,B,C,D,E,
F,G per drawing GE42819
Natural Gas Approved
Vmax = 30 VDC
Imax = 226 mA
Ci = 5 nF
Li = 0.55 mH
Pi = 1.4 W
Voc = 9.6 VDC
Isc = 3.5 mA
Ca = 3.6 uF
La = 100 mH
Po = 8.4 mW
T5(Tamb ≤ 80C)
T6(Tamb ≤ 75C)
Type 4X, IP66
Single Seal Device
XP Explosion-proof
Class I Division 1 GP B,C,D
NI Non-incendive
Class I Division 2 GP A,B,C,D
DIP Dust Ignition-proof
Class II, III Division 1 GP E,F,G
S Suitable for Use
Class II, III Division 2 GP F,G
Natural Gas Approved
− − −
T5(Tamb ≤ 80C)
T6(Tamb ≤ 75C)
Type 4X, IP66
Single Seal Device
DVC60x5
(x = 1,2,3)
IS Intrinsically Safe
Class I,II,III Division 1 GP A,B,C,D,
E,F,G per drawing GE42819
Vmax = 30 VDC
Imax = 100 mA
Ci = 0 uF
Li = 0 mH
Pi = 160 mW
T4(Tamb ≤ 125C)
T5(Tamb ≤ 95C)
T6(Tamb ≤ 80C)
Type 4X, IP66
XP Explosion-proof
Class I Division 1 GP A,B,C,D
NI Non-incendive
Class I Division 2 GP A,B,C,D
DIP Dust Ignition-proof
Class II, III Division 1 GP E,F,G
S Suitable for Use
Class II, III Division 2 GP F,G
− − −
T4(Tamb ≤ 125C)
T5(Tamb ≤ 95C)
T6(Tamb ≤ 80C)
Type 4X, IP66
1