iv
iv
Transducer Block (TB) Menu Structure (Continued)
PARAMETER LABEL MENU STRUCTURE
I/O Processor Man Recovery
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Shutdown Recovery.I/O Processor Man
Recovery
I/O Processor Shutdown
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Shutdown Trigger.I/O Processor
Shutdown
Inlet Pressure TB > Configure/Setup > Detailed Setup > Valve and Actuator > Valve > Inlet Pressure
Input Characterization
TB > Configure/Setup > Detailed Setup > Response Control > Input Characterization
TB > Device Variables > Input Characterization
Integrator Limited Hi TB > Device Diagnostics > Status > Self Test Status > Self Test Status.Integrator Limited Hi
Integrator Limited Lo TB > Device Diagnostics > Status > Self Test Status > Self Test Status.Integrator Limited Lo
Integrator Suspended TB > Device Diagnostics > Status > Self Test Status > Self Test Status.Integrator Suspended
IOP Failure TB > Device Diagnostics > Status > Self Test Status > Self Test Status.IOP Failure
Last Calibration Type TB > Configure/Setup > Detailed Setup > Instrument > Last Calibration Type
Leak Class TB > Configure/Setup > Detailed Setup > Valve and Actuator > Trim > Leak Class
Length Units TB > Configure/Setup > Detailed Setup > Instrument > Length Units
Lever Arm Length TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Lever Arm Length
Lever Style TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Lever Style
Lost Static Data TB > Device Diagnostics > Status > Block Error > Block Error.Lost Static Data
Lower Bench Set TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Lower Bench Set
MAI Channel 1 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 1
MAI Channel 2 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 2
MAI Channel 3 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 3
MAI Channel 4 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 4
MAI Channel 5 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 5
MAI Channel 6 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 6
MAI Channel 7 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 7
MAI Channel 8 TB > Configure/Setup > Detailed Setup > MAI Channel Map > MAI Channel 8
Maint Active TB > Configure/Setup > Detailed Setup > Alert Handling > Simulate Active Alerts > Maint Active
Maintenance Enable TB > Configure/Setup > Detailed Setup > Alerts > PlantWeb Alert Enable > Maintenance Enable
Maintenance Suppress TB > Configure/Setup > Detailed Setup > Alerts > PlantWeb Alert Reporting > Maintenance Suppress
Maximum Recorded Supply
Pressure
TB > Device Diagnostics > Device Record > Maximum Recorded Supply Pressure
Maximum Recorded Supply
Pressure Time
TB > Device Diagnostics > Device Record > Maximum Recorded Supply Pressure Time
Maximum Recorded
Temperature
TB > Device Diagnostics > Device Record > Maximum Recorded Temperature
Maximum Recorded
Temperature Time
TB > Device Diagnostics > Device Record > Maximum Recorded Temperature Time
Maximum Supply Pressure TB > Configure/Setup > Detailed Setup > Instrument > Maximum Supply Pressure
Minimum Recorded Supply
Pressure
TB > Device Diagnostics > Device Record > Minimum Recorded Supply Pressure
Minimum Recorded Supply
Pressure Time
TB > Device Diagnostics > Device Record > Minimum Recorded Supply Pressure Time
Minimum Recorded
Temperature
TB > Device Diagnostics > Device Record > Minimum Recorded Temperature
Minimum Recorded
Temperature Time
TB > Device Diagnostics > Device Record > Minimum Recorded Temperature Time
MLFB Error TB > Device Diagnostics > Status > Self Test Status > Self Test Status.MLFB Error
Nominal Supply Pressure TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Nominal Supply Pressure
Out of Service TB > Device Diagnostics > Status > Block Error > Block Error.Out of Service
Outlet Pressure TB > Configure/Setup > Detailed Setup > Valve and Actuator > Valve > Outlet Pressure
Outblock Selection TB > Configure/Setup > Detailed Setup > Response Control > Outblock Selection
Output Block Timeout TB > Configure/Setup > Detailed Setup > Alerts > Configuration Alerts > Output Block Timeout
Output Block Timeout Alert
TB > Configure/Setup > Detailed Setup > Alerts > Configuration Alerts > Output Block Timeout > Elect Active.Output Block
Timeout Alert
Output Block Timeout Alert
Enable
TB > Configure/Setup > Detailed Setup > Alerts > Configuration Alerts > Output Block Timeout > Elect Active.Output Block
Timeout Alert Enable
Output Block Timeout Manual
Recovery
TB > Configure/Setup > Detailed Setup > Alerts > Configuration Alerts > Output Block Timeout > Shutdown Recovery.Output
Block Timeout Manual Recovery
−Continued−