MAS2600: Ordering Information Reference Manual
August 2023 RM 6000-01-001-24
11
MAS 2600 Ordering Information
Type
A
Absolute Transducer
G
Gauge Transducer
H
High Temperature Gauge Transducer
Transducer Ranges
1
3,5 mH
2
O gauge
2
7,0 mH
2
O gauge
3
16,0 mH
2
O gauge
4
35,0 mH
2
O gauge or 0,8 to 3,5 bar absolute
7
0,8 to 2,0 bar absolute
Temperature Sensor
0
without
1
Built-in Pt 100 (not available for IS installations)
Cable (length in meters)
XX
Standard cable (-20° to 80° C)
Maximum length: Hazardous area 44 m, Safe area 300 m
XX
High temperature cable (-20° to 125° C) (-20° to 80° C for IS installation)
Maximum length: Hazardous area 34 m, Safe area 300 m
Mounting
0
without fittings
1
brackets for internal mounting
2
pole mounting
3
1” pipe end mounting
4
flange mounting DN 25
5
flange mounting DN 40
6
flange mounting DN 50
9
flexible rubber tube mounting (add length in mm)
P
flexible PTFE tube mounting (add length in mm)
V
DN 25 flange with 1” ball valve mounting
A - M
replacement
Amplifier Box
0
not supplied
1
standard box with PG 11 / PG 11
2
standard box with PG 11 / PG 13,5
3
standard box with PG 11 / PG 16
5
standard box with PG 13,5 / PG 13,5
Amplifier PCB
0
not supplied
P
programmable output range gauge
D
differential output range gauge
X X X - XX - X / X X