Reference Manual MAS2600: Ordering Information
RM 6000-01-001-24 August 2023
26
Amplifier PCB
MAS 2600 -XXX-XX-X/XX
The PCB is available in different types for the different transducers.
Amplifier PCB
Amplifier PCB
0 Without amplifier PCB.
P Programmable output range. The amplifier can be calibrated to 4-20 mA out-
put in whatever range wanted within the transducer range. Calibration is
made by means of dip switches and potentiometers.
D Differential output range. The output can be adjusted to 12 mA output with
no pressure applied. With pressure or vacuum, the output goes against 20
mA and 4 mA respectively. Full-scale and zero point calibration by means of
software, e.g. tank monitoring software.