6 Model 3700 Transmitters or Model 3350 Peripherals - Field Mount
Planning
1.2 Choose a location
Choose a location for the transmitter based on the requirements described below.
1.2.1 Environmental requirements
Install the Model 3350 or Model 3700 where the ambient temperature is between –4 to
+140 °F (–20 to +60 °C).
1.2.2 Dimensions
Figure 1-2: Face view dimensions
WARNING!
Improper installation in a hazardous area can cause an explosion.
Install the transmitter in an area that is compatible with the rating on the approvals tag. See Figure
1-3.
inches (mm)
Rotate display cover as needed
Rotate mounting bracket as
needed
2 13/16
(71)
4 x 5/16-inch
(9 mm) diameter
9 3/16
(234)
4
(102)
3 5/8
(92)
6
(152)
11
(279)
12
(305)