8 Micro Motion 7829 Viscomaster Dynamic Viscosity Meter
Materials of construction
Weight
Electrical
Wetted parts 316L Stainless steel
Tine finish PFA laminated
(1)
(1) PFA is applied only to the tines for its anti-stick properties not for corrosion protection.
Electronics enclosure Sand cast low copper alloy
Polyurethane paint finish
Weight 7.5 lb (3.4 kg) typical
Power supply requirement For transmitter
For mA outputs
20 to 28 VDC, 50 mA
22 mA per output
Outputs mA
Accuracy
Repeatability
Out-of-range
System alarm
Two externally powered 4–20 mA
±0.1% of reading, ±0.05% of full scale at 68 °F (20 °C)
±0.05% of full scale, over range –40 °F to +185 °F
(–40 °C to +85 °C)
3.9 or 20.8 mA on 4–20 mA
2 or 22 mA on 4–20 mA (Programmable alarm state)
Communications RS-485 (Modbus)
Electrical connection Screw terminal, cable entry to suit ½" NPT gland (20 mm adaptor available)