2.2 Mount the sensor
Use your common practices to minimize torque and bending load on process connections.
Tip
To reduce the risk of condensation problems, do not orient transmitters or sensor junction boxes
with their conduit openings pointing upward.
CAUTION!
Do not lift the sensor by the electronics or purge connections. Lifting the sensor by the
electronics or purge connections can damage the device.
Mounting the sensorFigure 2-3:
Notes
Do not use the sensor to support the piping.
The sensor does not require external supports. The flanges will support the sensor in any
orientation. (Some sensor models installed in very small, flexible pipeline have optional installation
instructions that allow for external supports.)
Mounting
10 Micro Motion ELITE