2 Micro Motion
®
Model D and DT Sensors Instruction Manual
Before You Begin continued
The D600 sensor and booster amplifier are available in any of the
configurations described in Table 2. Table 2 also lists the transmitters
that can be used with each configuration.
European installations
This Micro Motion product complies with all applicable European
directives when properly installed in accordance with the instructions in
this quick reference guide. Refer to the EC declaration of conformity for
directives that apply to this product.
The EC declaration of conformity, with all applicable European
directives, and the complete ATEX Installation Drawings and Instructions
are available on the internet at www.micromotion.com/atex or through
your local Micro Motion support center.
Information affixed to equipment that complies with the Pressure
Equipment Directive can be found on the internet at
www.micromotion.com/library.
Sensor components
Components of the sensor are illustrated on pages 3-6.
Table 2. D600 configurations and compatible transmitters
D600 sensor configuration
Booster amplifier location
Booster amplifier wiring
component
Connection to
transmitter Compatible transmitters
Integral to sensor Junction box 9-wire Model 1700/2700 (with integral core
processor)
Model 3500/3700 (9-wire)
RFT9739
RFT9712
Remote core processor
Core processor 4-wire Model 1700/2700
Model 3500/3700 (MVD)
Model 2500
Direct host
(1)
Remote from sensor Junction box 9-wire Model 1700/2700 (with integral core
processor)
Model 3500/3700 (9-wire)
RFT9739
RFT9712
Remote core processor
Core processor 4-wire Model 1700/2700
Model 3500/3700 (MVD)
Model 2500
Direct host
(1)
(1)A direct host is a user-supplied remote controller, PLC, or other device.

Other manuals for Emerson Micro Motion

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Micro Motion and is the answer not in the manual?

Emerson Micro Motion Specifications

General IconGeneral
CategoryMeasuring Instruments
ManufacturerEmerson
BrandMicro Motion
TypeCoriolis Flow Meter
Output4-20 mA, HART, Foundation Fieldbus, Profibus, Modbus
Power Supply24 V DC
MaterialStainless Steel, Hastelloy
Process ConnectionFlanged, Threaded
CertificationsATEX, IECEx, CSA, SIL
Pressure RatingVaries by model; up to 10, 000 psi (690 bar)
Temperature RangeVaries by model; -400 to 750°F (-240 to 400°C)