32 Powerdrive F300 Getting Started Guide
Issue Number: 5
Figure 3-15 Removal of line to ground varistors (size 11E)
To electrically disconnect the line to ground varistors, remove the two screws highlighted (1) above
and remove the bracket (2).
3.8.3 External filter
The external EMC filter for size 3, 4, 5 and 6 can be footprint or bookcase mounted.
For information on drive and EMC filter cross reference, refer to the Drive User Guide.
For further information refer to the Drive User Guide.
To avoid a fire hazard and maintain validity of the UL listing, adhere to the specified
tightening torques for the power and ground terminals.
1
2
1
WARNING
Powerdrive F300 Getting Started Guide English Iss2.book Page 32 Tuesday, July 28, 2015 3:23 PM