Page 73
›1.4 Efciency funct...‹ appears.
Another selection level appears.
Once the rst subitem
›disable recharge‹ is selected, ...
1.3.8 Increase retu...
04. 07. 2015
10:27
Activation
T ON
T OFF
T min
8.0K
4.0K
15.0°C
1.3.10 Post Heatin...
04. 07. 2015 10:27
Hysteresis
Time block 1
Time block 2
Time block 3
Time block 4
10.0K
1.4 Efciency funct...
04. 07. 2015 10:28
Disable recharge
OPERATION MODE
›1.3.8 Increase retu...‹ appears.
Parameters for return ow temperature
increase can be dened here.
Ask a tter before making
changes at this point.
Return to ›1.3 Basic functions‹.
Continue with ›Post Heating Request‹.
›1.3.10 Post Heatin...‹ appears.
The reheating control reacts to the values of
the top tank sensor. If the temperature falls
below ›t charge‹ minus the hysteresis, the
control activates the reheating cycle via the
heating boiler. When the set value is reached
the reheating cycle is stopped.
Return to ›1 Main menu‹.
Continue with ›Efciency functions‹.