Page 99
1.4.3 disable rech...
04. 07. 2015 10:39
45.0°C
Activation T min.
T min.tank
Activat.Tmin Float
45.0°C
1.4.3 disable recha...
04. 07. 2015 10:39
Emphasis
T targ.
T oating
Balanced
45.0°C
upper tank sensor
1.4.3 disable recha...
04. 07. 2015 10:39
T targ.
T oating
T min.tank
45.0°C
upper tank sensor
45.0°C
PROFESSIONAL MODE
Enter the minimum tank temperature
via ›T min tank‹.
Continue with ›Efcient tank-charge‹.
„Emphasis“ can be set as „High comfort“,
„Low comfort“, „Balanced“, „Low solar share“
or „High solar share“; it species the ratio of
recharge and solar yield.
Determine under ›T oating‹ whether
the temperature is to be measured
on the upper or lower tank sensor.
Continue to scroll.
Select the minimum temperature
via ›T min.tank‹.
Here, the efciency-optimized disable re-
charge is enabled and activated - possible for
all systems with heating boiler control.
Continue to scroll.