EL – Owner’s Manual – Rev.00 – September 2022 5
Output: O
2
with water vapour (H
2
O) and traces of H
2
3. COOLING WATER IN/OUT – (only liquid cooled electrolysers) please refer to the Cooling Loop
Connection Guide (COOLING WATER IN/OUT)
Push-fit female bulkhead connector (10mm outer diameter pipes) LLDPE
Input/Output: cooling water to cool down the device
4. H
2
OUT – please refer to the Hydrogen Outlet Connection Guide (H2 OUT)
¼" bspp female port
Output: 0.5 Nm³/h of H2, up to 35 barg, 99,9% purity
5. H2 VENT –please refer to the Hydrogen Vent Connection Guide (H2 VENT)
¼" bspp female port
Output: Periodical vent of up to 20 NL (H
2
and water) every 12 hours
6. FILL / DRAIN
10 mm CPC quick connector
During maintenance routine for filling the electrolyte into the device or for draining
and preparing it for transport.
7. START STOP – please refer to the Manual Start/Stop section below
Manual start and stop button to start and stop the device
8. POWER – please refer to the Electrical Connection Guide (POWER)Electrical Connection Guide
(POWER)
Manual power button to switch device on and off
9. ETH. – please refer to the Ethernet Port (ETH.) section below
Interface to access external Modbus control features of the electrolyser. Find more in
the chapter below.
10. DRY CON. – please refer to the Dry Contact Connection Guide (Optional) (DRY CON.)
Interface to connect device to external sensors for emergency stops
11. WiFi Button – please refer to the Pairing the device to the cloud section below
Manual button to activate/deactivate WiFi
12. ANT. – Antenna port SMA male
The device can be connected to the local network via Bluetooth and Wi-Fi, enabling
real-time updates and monitoring for the operator via the Enapter App and cloud. A
miniature antenna can be attached to this port to increase the amplification.
Do not touch the port when the device is powered on!
13. On/Off Button (only in AC version) or Breaker (only in DC version) – please refer to the Electrical
Connection Guide (POWER)Electrical Connection Guide (POWER)
Integrated magnetothermal circuit breaker to protect the electrolyser from
overcurrent and short-circuits.
14. Fuses (only in AC version) or Breaker (only in DC version) – please refer to the Electrical
Connection Guide (POWER)Electrical Connection Guide (POWER)
Integrated magnetothermal circuit breaker to protect the electrolyser from
overcurrent and short-circuits.
15. Handle Bars – please refer to the Transport section below
For easier transportation