EasyManuals Logo

Endress+Hauser Cerabar M PMP51 Technical Information

Endress+Hauser Cerabar M PMP51
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Pressure transmitter with ceramic and
metal sensors
Application
The device is used for the following measuring tasks:
Absolute pressure and gauge pressure measurement in gases, steams or liquids in
all areas of process engineering and process measurement technology
Level, volume or mass measurement in liquids
High process temperature
without diaphragm seals up to 130 °C (266 °F), for a maximum of 60 minutes
150 °C (302 °F)
with diaphragm seals up to 400 °C (752 °F)
High pressure up to 400 bar (6 000 psi)
International usage thanks to a wide range of approvals
Your benefits
Very good reproducibility and long-term stability
High reference accuracy up to ±0.10 %
as PLATINUM version: ±0.075 %
Turn down up to 100:1
Uniform platform for differential pressure, hydrostatics and pressure (Deltabar M
– Deltapilot M – Cerabar M)
Simple, fast commissioning through a user interface designed for real-world
applications
Used for process pressure monitoring up to SIL 2, certified to IEC 61508 Edition
2.0 and IEC 61511 by TÜV NORD
The patented TempC Membrane for the diaphragm seal reduces measured errors
caused by environmental and process temperature influences to a minimum
ASME-BPE-compliant device versions
Products
Solutions Services
Technical Information
Cerabar M
PMC51, PMP51, PMP55
Process pressure measurement
TI00436P/00/EN/28.19
71438042
2019-04-16

Table of Contents

Other manuals for Endress+Hauser Cerabar M PMP51

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Cerabar M PMP51 and is the answer not in the manual?

Endress+Hauser Cerabar M PMP51 Specifications

General IconGeneral
Device TypePressure transmitter
Measuring PrinciplePiezoresistive
Measured variablePressure
Output Signal4 to 20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Process Temperature-40°C to +150°C
Ambient Temperature-40°C to +85°C
Process Connectionflanges
Housing materialAluminum
Wetted parts materialStainless steel
CommunicationHART, PROFIBUS PA, Foundation Fieldbus
ApprovalsATEX, IECEx, SIL, NEPSI, FM, CSA
Protection ClassIP66
MaterialAluminum
Electrical ConnectionM12 connector
Power supply10.5 to 45 V DC (depending on communication protocol)

Related product manuals