Cerabar S
Endress+Hauser 87
PMP75 This overview does not mark options which are mutually exclusive.
10 Approval:
A For non-hazardous areas
1 ATEX II 1/2 G Ex ia IIC T6
6 ATEX II 1/2 G Ex ia IIC T6, Overfill prevention WHG
2 ATEX II 1/2 D
4 ATEX II 1/3 D
8 ATEX II 1 GD Ex ia IIC T6
3 ATEX II 1/2 GD Ex ia IIC T6
5 ATEX II 2 G Ex d IIC T6 Gb
7 ATEX II 3 G Ex nA II T6
S FM IS, Class I, II, III Division 1, Groups A – G; NI Class I Division 2, Groups A – D; AEx ia
T FM XP, Class I Division 1, Groups A – D; AEx d
Q FM DIP, Class II, III Division 1, Groups E – G
R FM NI, Class I, Division 2, Groups A – D
U CSA IS, Class I, II, III Division 1, Groups A – G; Class I Division 2, Groups A – D, Ex ia
V CSA XP, Class I Division 1, Groups B – D; Ex d
W CSA Class II, III Division 1, Groups E – G (Dust-Ex)
G NEPSI Ex d IIC T6
H NEPSI Ex ia IIC T6
L TIIS Ex d IIC T6
I IECEx Zone 0/1 Ex ia IIC T6
M IEC Ex d IIC T6 Gb
B Combined certificates: ATEX II 1/2 G Ex ia IIC T6 + II 2 G Ex d IIC T6
C Combined certificates: FM IS and XP Class I Division 1, Groups A – D
D Combined certificates: CSA IS and XP Class I Division 1, Groups A – D
E Combined certificates: FM/CSA IS and XP Class I Division 1, Groups A – D
F Combined certificates:
ATEX II Ex ia / Ex d + FM/CSA IS + XP
ATEX II 1/2G Ex ia IIC T6+
ATEX II 2G Ex d IIC T6+
FM/CSA IS + XP Cl.I Div.1 Gr.A-D
20 Output; Operation:
A 4 to 20 mA HART, operation outside, LCD (→ see Fig. ➀, n)
B 4 to 20 mA HART, operation inside, LCD (→ see Fig. ➀, o)
C 4 to 20 mA HART, operation inside (→ see Fig. o)
M PROFIBUS PA, operation outside, LCD (→ see Fig. ➀, n)
N PROFIBUS PA, operation inside, LCD (→ see Fig. ➀, o)
O PROFIBUS PA, operation inside (→ see Fig. o)
P FOUNDATION Fieldbus, operation outside, LCD (→ see Fig. ➀, o)
Q FOUNDATION Fieldbus, operation inside, LCD (→ see Fig. ➀, o)
R FOUNDATION Fieldbus, operation inside (→ see Fig. o)
30 Housing; Cable entry; Protection:
A Aluminum T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Gland M 20x1.5
B Aluminum T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Thread G 1/2
C Aluminum T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Thread 1/2 NPT
D Aluminum T14 housing, optional display on the side, IP66/67/NEMA 4X/ 6P, M 12x1 PA plug,
E Aluminum T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, 7/8" FF plug
F Aluminum T14 housing, optional display on the side, IP 65/NEMA 4X, Han7D plug, 90°
1 AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Gland M 20x1.5
2 AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Thread G 1/2
3 AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Thread 1/2 NPT
4 AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, M 12x1 PA plug
5 AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, 7/8" FF plug
6 AISI 316L T14 housing, optional display on the side, IP 65/NEMA 4X, Han7D plug, 90°
R T17 316L Hygiene IP66/68 NEMA6P; M20 gland, T17 = side cover
S T17 316L Hygiene IP66/68 NEMA6P; G1/2 thread, T17 = side cover
T T17 316L Hygiene IP66/68 NEMA6P; NPT1/2 thread, T17 = side cover
U T17 316L Hygiene IP66/67 NEMA6P; M12 plug, T17 = side cover
V T17 316L Hygiene IP66/68 NEMA6P; 7/8" plug, T17 = side cover
40 Sensor range; Sensor over pressure limit (= OPL):
Sensors for gauge pressure
Measurement limits: –100 % (–1 bar) to +100 % of sensor nominal value
Sensor rated value (URL) OPL (over pressure limit)
1F 400 mbar/40 kPa/6 psi 6 bar/600 kPa/90 psi