EasyManua.ls Logo

Endress+Hauser Deltapilot M FMB51 - Page 14

Endress+Hauser Deltapilot M FMB51
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Cerabar M, Deltabar M, Deltapilot M / 4...20 mA HART
14 Endress+Hauser
3.3.3 Seal for flange mounting
P01-FMD7xxxx-11-xx-xx-xx-002
Fig. 11: Mounting the versions with a flange
1 Process isolating diaphragm
2Seal
#
Warning!
The seal is not allowed to press against the process isolating diaphragm as this could affect the
measurement result.
3.3.4 Thermal insulation – PMP55
The PMP55 may only be insulated up to a certain height. The maximum permitted insulation height
is indicated on the devices and applies to an insulation material with a heat conductivity
0.04 W/(m x K) and to the maximum permitted ambient and process temperature ( see table
below). The data were determined under the most critical application "quiescent air".
P01-PMx5xxxx-11-xx-xx-xx-010
Fig. 12: Maximum permitted insulation height, here indicated on a PMP55 with a flange
l 0.04£
W
mK
T
P
T
A
PMP55
Ambient temperature (T
A
) 70°C (158°F)
Process temperature (T
P
) Max. 400°C (752°F), depending on the diaphragm seal filling oil used (see
TI00436PEN)

Table of Contents

Other manuals for Endress+Hauser Deltapilot M FMB51

Related product manuals