XA00286P-C Deltapilot S
10
Safety instructions:
Installation
FMB70_01
å
1
A Power supply
B Zone 1, Zone 21, Electronic
C Zone 0, Zone 20, Process
1 Certified associated apparatus
2FMB70
Comply with the installation and safety instructions in the Operating Instructions.
Install the device according to the manufacturer's instructions and any other valid standards and
regulations.
Only install the devices in media for which the wetted materials have sufficient durability.
The device is designed for operation in Zone 21 or Zone 1 (housing) as well as Zone 20 or Zone 0
(process connection). Its suitability in the event of potentially explosive gas-air and dust-air mixtures
occurring simultaneously requires further assessment.
The type of protection changes as follows when the devices are connected to certified intrinsically
safe circuits of Category ib: Ex ib IIC T6 or Ex ib IIB T4.
When connecting an intrinsically safe ib circuit, do not operate the sensor at Zone 0.
The intrinsically safe input power circuit of the device is isolated from ground potential and has a
dielectric strength of at least 500 V
rms
with respect to it. For devices with integrated overvoltage
protection (optional), the dielectric strength is min. 290 V
rms
to earth.
After aligning (rotating) the housing, retighten the fixing screw.
Avoid impact or friction sparks for light metal flanges or flange faces (e.g. titanium, zirconium).
Safety instructions:
Zone 0
Only operate devices in potentially explosive vapour/air mixtures under atmospheric conditions:
–20 °C T +60 °C
0.8 bar p 1.1 bar
If no potentially explosive mixtures are present, or if additional protective measures have been
taken, according to EN 1127-1, the transmitters may be operated under other atmospheric
conditions in accordance with the manufacturer's specifications.
Associated apparatus with galvanic isolation between the intrinsically safe and non-intrinsically safe
circuits are preferred.
Safety instructions:
Zone 20/21
Seal the cable entry or piping tight (see housing ingress protection in the table).
Only use cable glands which are suited for dust-Ex protection: e.g. with ATEX/IECEx Ex t approval or
ATEX/IECEx Ex e approval (min. IP65 ingress protection). Lay connecting cable and secure.
B
A
1
2
C