2.2.2 Pressure measurement in gases
Mount Deltapilot S with shutoff device above the tapping point so that any condensate can
flow into the process.
2.2.3 Pressure measurement in steams
Mount Deltapilot S with siphon above the tapping point.
Fill the siphon with liquid before commissioning.
The siphon reduces the temperature to almost the ambient temperature.
2.2.4 Pressure measurement in liquids
Mount Deltapilot S with the shutoff device below or at the same level as the tapping point.