Parameter description (Local operation and FieldCare) Cerabar S/Deltabar S/Deltapilot S FOUNDATION Fieldbus
198 Endress+Hauser
MAT. PROC. CONN. +
(360)
Selection
For selecting and displaying the material of the process connection (P+).
See also parameter description for MAT. PROC. CONN. -
Options:
•Not used
•Unknown
Special
Steel
304 st. steel
316 st. steel
Alloy C
•Monel
•Tantalum
Titanium
•PTFE (Teflon)
316L st. steel
•PVC
•Inconel
•PVDF
•ECTFE
Factory setting:
As per order specifications
MAT. PROC. CONN. - (361)
Selection
For selecting and displaying the material of the process connection (P–).
See also parameter description for MAT. PROC. CONN. +
Prerequisite:
Deltabar S differential pressure transmitter
SEAL TYPE (362)
Selection
For selecting and displaying the material of the process seal.
Options:
•Not used
•Unknown
Special
FKM Viton
•NBR
•EPDM
•Urethane
•IIR
•Kalrez
FKM Viton oxyg
•CR
•MVQ
•PTFE glass
•PTFE graphite
PTFE oxygen
Copper
Copper f. oxygen
Factory setting:
As per order specifications
Table 25: OPERATING MENU TRANSMITTER INFO SENSOR DATA
Parameter name Description
SENSOR SER. No. (250)
Display
Displays the serial number of the sensor (11 alphanumeric characters).
PRESS. SENS LOLIM (484)
Display
Displays the lower measuring limit of the sensor.
PRESS. SENS HILIM (485)
Display
Displays the upper measuring limit of the sensor.
MINIMUM SPAN (591)
Display
Displays the smallest possible span.