Cerabar S/Deltabar S/Deltapilot S FOUNDATION Fieldbus Parameter description (Local operation and FieldCare)
Endress+Hauser 199
SENSOR MEAS.TYPE (581)
Display
Deltabar S = Differential
Cerabar S with gauge pressure sensors = Relative
Cerabar S with absolute pressure sensors = Absolute
Deltapilot S = Relative
Displays the sensor type.
Pmin SENS.DAMAGE (251)
Display
Displays the minimum permitted absolute pressure of the sensor (resistance to vacuum).
Pmax SENS.DAMAGE (252)
Display
Displays the maximum permitted absolute pressure of the sensor (resistance to
overpressure).
MAT. MEMBRANE (365)
Display
Displays the material of the process isolating diaphragm.
Factory setting:
As per version in the order code
See also Technical Information TI00382P (Deltapilot S), TI00383P (Cerabar S) or
TI00416P (Deltapilot S), "Ordering information" section.
FILLING FLUID (366)
Display
Displays the filling fluid.
Tmin SENSOR (368)
Display
Displays the lower nominal temperature limit of the sensor.
Tmax SENSOR (369)
Display
Displays the upper nominal temperature limit of the sensor.
SENS H/WARE REV (487)
Display
Displays the revision number of the sensor hardware.
e.g.: 1
Table 26: OPERATING MENU TRANSMITTER INFO FF DATA
Parameter name Description
DEVICE ID (987)
Display
The DEVICE ID is the unique device ID in the control system or the FF bus. It consists of
the manufacturer ID (452B48), device type number and device serial number.
Examples:
Deltabar S: 452B481009-6B032A0109D
Deltapilot S: 452B48100B-6B032A0109E
Cerabar S: 452B481007-6B032A0109F
DEVICE REVISION (986)
Display
Displays the revision or version of a complete device (HW+SW) within a device type.
DD REVISION (985)
Display
Displays the DD version initially certified.
DEVICE ADDRESS (984)
Display
Displays the device address currently configured and valid.
The factory setting is 247.
Table 25: OPERATING MENU TRANSMITTER INFO SENSOR DATA