XA00639F-A Levelflex FMP51/52/53/54/55/56/57
Endress+Hauser 21
Probe design: compact / 探针设计:一体化型
Probe and electronics housing: Zone 1 / 探针和电子部件外壳:区域 1
FMP51
Position / 位置 5 (Housing / 外壳 ) = B
Position / 位置 3
(Power Supply; Output /
电源;输出 ) =
Temperature class /
温度组别
P 1 P 2 P 3 P 4 P 5 P 6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A; C:
1 canal used /
使用管道 1
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 51 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 66 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 80 °C 80 °C 80 °C 135 °C 68 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 80 °C 80 °C 80 °C 200 °C 48 °C 200 °C –40 °C –40 °C –40 °C - -
C:
2 canal used /
使用管道 2
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 51 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 66 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 78 °C 78 °C 78 °C 135 °C 64 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 78 °C 78 °C 78 °C 200 °C 48 °C 200 °C –40 °C –40 °C –40 °C - -
K, L T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 51 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 66 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 76 °C 76 °C 76 °C 135 °C 62 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 76 °C 76 °C 76 °C 200 °C 46 °C 200 °C –40 °C –40 °C –40 °C - -
Position / 位置 5 (Housing / 外壳 ) = C
Position / 位置 3
(Power Supply; Output /
电源;输出 ) =
Temperature class /
温度组别
P 1 P 2 P 3 P 4 P 5 P 6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A; C:
1 canal used /
使用管道 1
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 53 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 68 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 80 °C 80 °C 80 °C 135 °C 70 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 80 °C 80 °C 80 °C 200 °C 56 °C 200 °C –40 °C –40 °C –40 °C - -
C:
2 canal used /
使用管道 2
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 53 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 68 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 78 °C 78 °C 78 °C 135 °C 66 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 78 °C 78 °C 78 °C 200 °C 53 °C 200 °C –40 °C –40 °C –40 °C - -
K, L T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 53 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 68 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 76 °C 76 °C 76 °C 135 °C 64 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 76 °C 76 °C 76 °C 200 °C 51 °C 200 °C –40 °C –40 °C –40 °C - -