EasyManua.ls Logo

Endress+Hauser Levelflex FMP55 - Page 40

Endress+Hauser Levelflex FMP55
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connection Levelflex FMP55 HART
40 Endress+Hauser
Connection examples for the switch output
3+
+
-
4-
A0015909
 12 Connection of a relay
Suitable relays (examples):
Solid-state relay: Phoenix Contact OV-24DC/480AC/5 with
mounting rail connector UMK-1 OM-R/AMS
Electromechanical relay: Phoenix Contact PLC-RSC-12DC/21
3+
2
1
+
4-
A0015910
 13 Connection of a digital input
1 Pull-up resistor
2 Digital input
For optimum interference immunity we recommend to connect an external resistor
(internal resistance of the relay or Pull-up resistor) of < 1 000 Ω.

Other manuals for Endress+Hauser Levelflex FMP55

Related product manuals