Liquiphant FTL31
Endress+Hauser 13
Short tube version
The use of the short tube ensures that the switch point is at the same level as in the previous
Liquiphant FTL260 model when an identical thread is selected. In this way, the device can be
replaced quickly and easily. (Applies for process connections G 1" weld-in adapter for flush-mounted
installation, MNPT 1" and R 1")
A
B
116.8 (4.6)
13 (0.51)
25 (0.98)
128 (5.04)
C
C
A0022122
Dimensions mm (in)
A Liquiphant FTL31 with short tube
B Liquiphant FTL260
C Switch point
Installation in pipes
During installation, pay attention to the position of the fork in order to minimize turbulence in the
pipe.
ø >50 (2.0)
<5 m/s (16 ft/s)
ø >10 (0.4)
A0021357