Liquiphant FTL51B Mounting
Endress+Hauser 13
4.1.6 Weld-in adapter with leakage hole
Weld in the welding neck in such a way that the leakage hole is pointing downwards. This
enables any leaks to be detected quickly.
316L
A0039230
 10 Weld-in adapter with leakage hole
4.2 Mounting the measuring device
4.2.1 Required tools
Open-ended wrench, Allen key
4.2.2 Installation
Horizontal installation in vessels
Align the tuning fork with the marking
316L/G1
A0039125
 11 Markings to align the tuning fork
Use the marking to align the tuning fork in such a way that medium can run off easily and
deposit buildup is avoided.
Markings may include the following:
Material specification, thread description or circle on the hexagonal nut or on the weld-in
adapter
The II symbol on the back of the flange or Tri-Clamp