A0042709
A Horn antenna: antenna length + 50 mm (2 in); min. 200 mm (7.87 in)
A Planar antenna: 1 m (3.28 ft)
C 150 to 300 mm (5.91 to 11.8 in); (water-based medium up to ε
r
= 2)
H > 1.5 m (4.92 ft)
Mounting cladded flanges
Note the following for cladded flanges:
Use the same number of flange screws as the number of flange bores provided.
Tighten the screws with the necessary torque (see Table).
Retighten after 24 hours or after the first temperature cycle.
Depending on the process pressure and temperature, check and retighten the screws, where
necessary, at regular intervals.
The PTFE flange cladding normally acts simultaneously as a seal between the nozzle and the
device flange.
Flange size Number of screws Tightening torque
EN
DN50/PN16 4 45 to 65 Nm
DN80/PN16 8 40 to 55 Nm
DN80/PN40 8 999 to 999 Nm
DN100/PN16 8 40 to 60 Nm
DN150/PN16 8 75 to 115 Nm
ASME
2"/150lbs 4 40 to 55 Nm
3"/150lbs 4 65 to 95 Nm
3"/300lbs 8 40 to 55 Nm
4"/150lbs 8 45 to 70 Nm
4"/300lbs 8 55 to 80 Nm
6"/150lbs 8 85 to 125 Nm
6"/300lbs 12 999 to 999 Nm