Micropilot FMR53, FMR54
Endress+Hauser 55
FMR54
Horn antenna
Seal: graphite –196 to 280 °C (–321 to 536 °F)
GT19 housing (plastic PBT)
Temperature specifications: °C (°F)
T
p
T
a
P1
P2
P3
P4
P5
P6
A0019344
Power supply; output (item 2
in the product structure)
P1 P2 P3 P4 P5 P6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A -196
(-321)
80
(176)
80
(176)
80
(176)
280
(536)
13
(55)
280
(536)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
18
(64)
B
Switch output not used
-196
(-321)
76
(169)
76
(169)
76
(169)
280
(536)
13
(55)
280
(536)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
18
(64)
B
Switch output used
-196
(-321)
60
(140)
60
(140)
60
(140)
280
(536)
13
(55)
280
(536)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
18
(64)
C
Channel 2 not used
-196
(-321)
82
(180)
82
(180)
82
(180)
280
(536)
13
(55)
280
(536)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
18
(64)
C
Channel 2 used
-196
(-321)
74
(165)
74
(165)
74
(165)
280
(536)
13
(55)
280
(536)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
18
(64)
E, G
Switch output not used
-196
(-321)
79
(174)
79
(174)
79
(174)
280
(536)
13
(55)
280
(536)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
18
(64)
E, G
Switch output used
-196
(-321)
63
(145)
63
(145)
63
(145)
280
(536)
13
(55)
280
(536)
-40
(-40)
-40
(-40)
-40
(-40)
-196
(-321)
18
(64)
FMR54
Horn antenna
Seal: graphite –196 to 280 °C (–321 to 536 °F)
Housing GT20 (aluminum coated)
Temperature specifications: °C (°F)
T
p
T
a
P1
P2
P3
P4
P5
P6
A0019344
Power supply; output (item 2
in the product structure)
P1 P2 P3 P4 P5 P6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A -196
(-321)
81
(178)
81
(178)
81
(178)
280
(536)
54
(129)
280
(536)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-15
(+5)
B
Switch output not used
-196
(-321)
82
(180)
82
(180)
82
(180)
280
(536)
54
(129)
280
(536)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-15
(+5)
B
Switch output used
-196
(-321)
77
(171)
77
(171)
77
(171)
280
(536)
49
(120)
280
(536)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-15
(+5)
C
Channel 2 not used
-196
(-321)
82
(180)
82
(180)
82
(180)
280
(536)
54
(129)
280
(536)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-15
(+5)
C
Channel 2 used
-196
(-321)
79
(174)
79
(174)
79
(174)
280
(536)
51
(124)
280
(536)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-15
(+5)
E, G
Switch output not used
-196
(-321)
83
(181)
83
(181)
83
(181)
280
(536)
54
(129)
280
(536)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-15
(+5)
E, G
Switch output used
-196
(-321)
78
(172)
78
(172)
78
(172)
280
(536)
50
(122)
280
(536)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-15
(+5)
K, L -196
(-321)
77
(171)
77
(171)
77
(171)
280
(536)
50
(122)
280
(536)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-15
(+5)
1) -50 °C (-58 °F) for order code 580 ("Test, certificate") = JN ("Transmitter ambient temperature -50°C/-58°F")