Micropilot FMR67B PROFINET with Ethernet-APL
30 Endress+Hauser
316L housing, hygiene; process temperature –40 to +150 °C (–40 to +302 °F)
T
a
T
p
P2
P1
P3
P4
P5
A0032024
 34 316L housing, hygiene; process temperature range: –40 to +150 °C (–40 to +302 °F)
P1 = T
p
: –40 °C (–40 °F) |  T
a
: +76 °C (+169 °F)
P2 = T
p
: +76 °C (+169 °F) |  T
a
: +76 °C (+169 °F)
P3 = T
p
: +150 °C (+302 °F) |  T
a
: +41 °C (+106 °F)
P4 = T
p
: +150 °C (+302 °F) |  T
a
: –40 °C (–40 °F)
P5 = T
p
: –40 °C (–40 °F) |  T
a
: –40 °C (–40 °F)
316L housing, hygiene; process temperature –40 to +200 °C (–40 to +392 °F)
T
a
T
p
P2
P1
P3
P4
P5
A0032024
 35 316L housing, hygiene; process temperature –40 to +200 °C (–40 to +392 °F)
P1 = T
p
: –40 °C (–40 °F) |  T
a
: +76 °C (+169 °F)
P2 = T
p
: +76 °C (+169 °F) |  T
a
: +76 °C (+169 °F)
P3 = T
p
: +200 °C (+392 °F) |  T
a
: +32 °C (+90 °F)
P4 = T
p
: +200 °C (+392 °F) |  T
a
: –40 °C (–40 °F)
P5 = T
p
: –40 °C (–40 °F) |  T
a
: –40 °C (–40 °F)
Storage temperature
Without LCD display: –40 to +90 °C (–40 to +194 °F)
With LCD display: –40 to +85 °C (–40 to +185 °F)
Climate class
DIN EN 60068-2-38 (test Z/AD)
Installation height as per
IEC61010-1 Ed.3
Generally up to 5 000 m (16 404 ft) above sea level
Degree of protection
Test as per IEC 60529 and NEMA 250-2014
Housing
IP66/68, NEMA TYPE 4X/6P
IP68 test condition: 1.83 m under water for 24 hours.
Cable entries
Gland M20, plastic, IP66/68 NEMA TYPE 4X/6P
Gland M20, nickel-plated brass, IP66/68 NEMA TYPE 4X/6P
Gland M20, 316L, IP66/68 NEMA TYPE 4X/6P
Gland M20, hygiene, IP66/68/69 NEMA Type 4X/6P
Thread M20, IP66/68 NEMA TYPE 4X/6P

Table of Contents