Micropilot FMR67B PROFINET with Ethernet-APL
Endress+Hauser 55
Antenna flush mount, 80 mm (3 in), with UNI flange and purge air connection
1
2
3
4
5
A0046613
 64 Material; antenna flush mount, 80 mm (3 in), with UNI flange and purge air connection. Unit of
measurement mm (in)
1 Antenna: PTFE, seal material FKM Viton GLT
2 Process connection: 316L / 1.4404
3 Housing adapter: 316L / 1.4404
4 Threaded adapter, plug screw fitting: 316L / 1.4404
For NPT plug screw fitting: seal material PTFE tape
For G plug screw fitting or NPT adapter: seal material: FKM O-ring
5 Integrated purge air adapter: 316L / 1.4404
Antenna flush mount, 80 mm (3 in), with UNI flange, alignment unit and purge air connection
1
2
3
5
6
4
7
A0046614
 65 Material, antenna flush mount, 80 mm (3 in), with UNI flange, alignment unit and purge air connection
1 Antenna: PTFE, seal material FKM Viton GLT
2 Process connection: aluminum
3 Housing adapter: 316L / 1.4404
4 Threaded adapter, plug screw fitting, purge air adapter: 316L / 1.4404
For NPT plug screw fitting: seal material PTFE tape
For G plug screw fitting or NPT adapter: seal material: FKM O-ring
5 Sensor adapter with alignment unit: 316L / 1.4404
6 Screws: A4-70, A2-70
7 Clamping washer: 3.1645 / aluminum