Tankside Monitor NRF81 Operating menu
Endress+Hauser 175
"Temperature" submenu
Read access Maintenance
Navigation Setup → Advanced setup → Application → Tank configuration
→ Temperature
Liquid temp source
Navigation Setup → Advanced setup → Application → Tank configuration → Temperature
→ Liquid temp source
Description Defines source from which the liquid temperature is obtained.
Selection • Manual value
• HART device 1 ... 15 temperature
• AIO B1-3 value
• AIO C1-3 value
• AIP B4-8 value
• AIP C4-8 value
Factory setting Manual value
Additional information
Read access Operator
Write access Maintenance
Manual liquid temperature
Navigation Setup → Advanced setup → Application → Tank configuration → Temperature
→ Manual liquid temperature
Prerequisite Liquid temp source (→ 123) = Manual value
Description Defines the manual value of the liquid temperature.
User entry –50 to 300 °C
Factory setting 25 °C
Additional information
Read access Operator
Write access Maintenance