Proline Promag Installation
Endress+Hauser 13
L
CAUTION
Risk of damaging the magnetic coil
If transporting by forklift, do not lift the sensor by the metal casing.
This would buckle the casing and damage the internal magnetic coils.
A0029319
5 Installation
5.1 Installation conditions
5.1.1 Mounting position
Mounting location
h
A0029343
h ≥ 2 × DN
Installation in down pipes
Install a siphon with a vent valve downstream of the sensor in down pipes whose length h ≥
5 m (16,4 ft). This precaution is to avoid low pressure and the consequent risk of damage to
the measuring tube. This measure also prevents the system losing prime.