Installation Proline Promag
20 Endress+Hauser
Buried applications
A remote version with IP68 protection is optionally available for buried applications. The
measuring device meets the requirements of certified corrosion protection Im1/Im2/Im3
according to EN ISO 12944. It can be used directly in buried applications without having to
take any additional precautions for the measuring device. The device is mounted in
accordance with the usual regional installation regulations (e.g. EN DIN 1610).
A0029321
5.2 Mounting the measuring device
5.2.1 Required tools
For transmitter
For turning the transmitter housing: Open-ended wrench8 mm
For opening the securing clamps: Allen key3 mm
For turning the transmitter housing: Open-ended wrench8 mm
For opening the securing clamps: Allen key3 mm
Torque wrench
For wall mounting:
Open-ended wrench for hexagonal screw max. M5
For pipe mounting:
Open-ended wrench AF 8
Phillips head screwdriver PH 2
For turning the transmitter housing (compact version):
Phillips head screwdriver PH 2
Torx screwdriver TX 20
Open-ended wrench AF 7